The document also gives you requirements for inspections and maintenance. The Edition is a technical revision of the previous Edition. The committee also notes that there are 2 new definitions and 4 new illustrations to help clarify text in the standard. Now you need to get a copy, so head to Document Center Inc. Here you can search for and order from our collection of over a million documents. Have additional questions about standards? Please get in touch with us. You can reach us by phone or email info document-center.

All handrails and stair railing systems shall be provided with a clearance of not less than two and one- fourth inches 57mm between the handrail or railing and any other object. Floor opening covers shall be of any material that meets the strength requirements of the surrounding floor. Skylight screens E5.

The screen area of one square foot dimension of the should be tested by the manufacturer to screen. They shall also be of such show its capacity meets the requirements of construction and mounting that, under the application.

Wall opening barriers shall be of such construction and mounting that, when in place at the opening, the barrier is capable of withstanding a load, as specified in 5. Fixed E6. Treads of short flights should not be and for access to operating platforms for less than 13 inches mm of tread depth, any equipment that requires routine and their presence and location should be attention.

Changes in level elevation of facilitated to improve step identification less than 21 inches mm shall be through the use of visual cues, which achieved either by a ramp or stair. Stairs include: handrails; delineated nosing edges; serving as a required means of egress for tactile cues; warning signs; contrast in life safety evacuation shall comply with surface colors; and accent lighting. Some alternating conventional stair designs. Three point contact secondary access situations where it is not means that either both hands and one foot, practical to provide a conventional stairway, or both feet and one hand are in contact spiral stairs, ship ladders, or alternating with the climbing device at all times.

For more information refer to Figures 6. Fixed stairs shall be designed and constructed to carry a load of five times the normal anticipated live load, but never less than a concentrated load of 1, pounds Fixed stairs shall have a minimum clear width of 22 inches mm. Fixed stairs shall be E6. The International Building Code degrees. The International Building Code. Nosings shall have an E6. Any add-on nosings should be of a contrasting color or its equivalent to make the edge of the stair clearly visible.

All treads and E6. The tolerance between the largest one or more treads of the stairs. Flights of E6. Stair landings shall be no less than the width of the stair and a minimum of 30 inches mm in length measured in the direction of travel along the centerline of the landing see Section 6.

Stairs E6. During its swing, the door shall leave not less than one-half of the required width of the landing unobstructed. The door shall project not more than seven inches mm into the required width of the landing when the door is fully open. Vertical clearance headroom above any stair shall be at least 80 inches mm measured vertically from the edge of the nosing to the overhead obstruction.

The vertical clear- ance shall be continuous above the stairway to the point where the line intersects the landing below, one tread depth beyond the bottom riser. The clearance shall be maintained the full width of the stairway and landing. Spiral stairs, ship E6. Spiral stairs, ship inches mm shall have open risers.

Railing systems as specified in this standard, shall be provided on all open sides of all exposed stairways, stair landings and platforms. Railing systems shall be designed and installed in accordance with 5. Every flight of stairs shall be risers or less short flights are considered equipped with a handrail system as stairs and should meet all requirements for specified in 7. Stair width, stairs.

Treads of short flights should not be for the purposes of applying the provisions less than 13 inches mm , and their of this section shall be nominal width of the presence and location should be facilitated stair.

Nominal stair width is depicted below in Figure 7. Additional intermediate handrails each enclosed side and one stair-railing should be provided so that all portions of the system on each open side. The following E8. Readers often ask for information standards and documents can be reviewed regarding construction and demolition sites as supporting documents for this standard. Those with an interest from the version of the standard cited below be used: construction and demolition perspective should review A The scope of Operations.

Open navigation menu. Close suggestions Search Search. User Settings. Skip carousel. Carousel Previous. Carousel Next. What is Scribd? Explore Ebooks.

Bestsellers Editors' Picks All Ebooks. Explore Audiobooks. Bestsellers Editors' Picks All audiobooks. Explore Magazines. Editors' Picks All magazines. Explore Podcasts All podcasts. Difficulty Beginner Intermediate Advanced. Explore Documents. Ansi A Uploaded by Yimmy Moreno. Did you find this document useful? Is this content inappropriate? Report this Document. Flag for inappropriate content. Download now. Related titles.

Carousel Previous Carousel Next. Jump to Page. Search inside document. At the time it approved this standard, the A Committee had the following members: Keith Vidal, P. PAGE 1. Deflection of whole system at design load. Excessive or permanent deformation or breakage. Platform between runs of stairs. Denotes mandatory item. Denotes advisory item. Horizontal member of a stair on which a person steps. A tapered tread used to change the direction of stair runs. Every hatchway and chute floor opening shall be guarded by one of the following: 3.

However, the following requirements include, but are not limited to: 3. Figure 6. Figure 7. Related Interests Stairs Safety Transport. Dhimas Zakaria. Marcus Alvarez. How do you reconcile A Your email address will not be published.